Purpose:
This product is designed for creating coatings used in environments that require the dissipation of electrostatic charges from the protected surfaces. It is intended for the protection of machines, equipment, wooden and wood-like elements, and components made of plastics, operating in urban and industrial atmospheres, as well as in mining. It is meant to protect surfaces made of cast iron, steel, non-ferrous metals, wood, wood-like materials, and plastic materials used in underground mine workings in non-metallic and methane fields.
Characteristics:
A suspension of pigments and fillers in an alkyd and polyvinyl resin solution in organic solvents with the addition of auxiliaries.
Product properties:
A specialized paint for the mining and industrial sectors with the ability to conduct electrical charges. It prevents the accumulation of static charges on the painted surfaces, thus protecting against electrostatic discharges. The paint coating is resistant to chemical atmospheres, with significant resistance to prolonged exposure to diluted inorganic acids, alkalis, and oxidizing agents. It offers good mechanical resistance and adhesion to substrates, providing excellent corrosion protection. It is highly flexible, formable, and impact-resistant. The modified alkyd conductive paint creates very well-adhering, protective-decorative coatings with excellent opacity.
Packaging:
Available in various capacities: 1L, 5L, 10L, 20L. The paint is available in a full range of colors, including those matching the RAL color chart.
Selected technical parameters:
Density (at 20ºC) | max. 1.40 g/cm³ |
Viscosity (DIN cup Ø4 at 20ºC) *) | 30 ÷ 70 s |
Qualitative coverage | first degree |
Gloss | matte, satin |
Thinning | chlorinated rubber-polyvinyl thinner |
Color | color palette |
Tool cleaning | immediately after use with thinner |
Content of solid components | at least 50% |
Flammability | flammable in liquid form (the coating after drying is non-flammable) |
Flash point | 40 ºC |
Coverage | up to 12 m²/L for one coat |
Substrate temperature | no lower than 5 ºC, higher by 3 ºC than the dew point temperature |
Ambient temperature | no lower than 5 ºC (optimal above 10 ºC) |
Application methods | hydrodynamic spray, pneumatic spray, brush, roller |
Recommended number of layers depending on desired thickness | 1-3 |
Recommended dry film thickness | 40 μm (for one layer) |
Drying time of the coating (at 20±2 ºC and relative humidity 65±5%) |
Degree 1 – min. 20 min. Degree 4 – max. 4 hours Degree 7 – max. 8 hours |
Time before applying the next layer | Spray application: after approximately 1 hour Brush or roller application: after 4 hours |
Surface resistance of the dry coating | < 9x10⁴ Ω [Ohm] |
VOC content limit (cat. A/i/FR=500 g/l) (2010) **) |
max. 490 g/l |
General instructions | Do not mix with water-based products. Stir before use and after long breaks in work |
*) modified to meet customer requirements **) in the commercial version The tested parameters may change depending on environmental conditions, |
The product complies with the Company CHEMIKA's Internal Standard.
It has the PZH (State Hygienic Institute) Certificate.
The product has obtained the CERTIFICATE authorizing the marking of the product with the safety mark.